Climate Device Controller Blueprint

This blueprint controls climate devices (heaters, AC, humidifiers, etc.) based on environmental sensors, window/door states, and schedules.

Supported Device Types

Supports any controllable device type through custom actions:

  • Switches (traditional on/off control)
  • Climate entities (HVAC, air conditioners)
  • Smart remotes (IR/RF commands for AC units)
  • Scripts and scenes
  • Any other controllable entity

Features

  • Automatic on/off based on target value (temperature, humidity, etc.)
  • Hysteresis window to prevent rapid on/off cycling
  • Force ON override (manual override to keep device always on)
  • Window/door sensor integration (turns off when open for efficiency)
  • Decay duration (waits before reacting to door/window changes)
  • Emergency threshold (forces device ON below critical value)
  • Schedule support (only runs during scheduled times)
  • Power monitoring (detects device malfunction)
  • House-wide and room-specific window/door sensors

Control Logic (Priority Order)

  1. If Force ON switch is ON → FORCE ON (manual override)
  2. If value is below emergency threshold → FORCE ON (safety override)
  3. If control switch is OFF → FORCE OFF
  4. If environment not sealed OR schedule not active → OFF
  5. If value at or above target → OFF (target reached)
  6. If value below turn-on threshold (target - hysteresis) → ON
  7. Otherwise → maintain current state (in hysteresis zone)

Hysteresis Example

Prevents rapid cycling:

  • Target humidity: 30%, Hysteresis window: 5%
  • Device turns OFF when humidity reaches 30%
  • Device turns ON when humidity drops to 25% (30% - 5%)
  • Between 25-30%: device maintains its current state

Window/Door Logic

  • "House closed" = ALL house windows are closed (for decay duration)
  • "Room closed" = ALL room windows AND doors are closed (for decay duration)
  • Device can run if EITHER house OR room is fully closed

Power Monitoring

If device is ON but power consumption is below threshold for decay duration, it's flagged as problematic (possible malfunction).

Requirements

  • Device entity to monitor state (switch, climate, etc.)
  • Custom actions for turning device on/off
  • Control switch (master enable/disable)
  • Environment sensor(s) for current value
  • Target value entity (input_number)