# Climate Device Controller Blueprint for Home Assistant
|
|
# =============================================================================
|
|
# This blueprint controls climate devices (heaters, AC, humidifiers, etc.)
|
|
# based on environmental sensors, window/door states, and schedules.
|
|
#
|
|
# Supports any controllable device type through custom actions:
|
|
# - Switches (traditional on/off control)
|
|
# - Climate entities (HVAC, air conditioners)
|
|
# - Smart remotes (IR/RF commands for AC units)
|
|
# - Scripts and scenes
|
|
# - Any other controllable entity
|
|
#
|
|
# Features:
|
|
# - Automatic on/off based on target value (temperature, humidity, etc.)
|
|
# - Hysteresis window to prevent rapid on/off cycling
|
|
# - Force ON override (manual override to keep device always on)
|
|
# - Window/door sensor integration (turns off when open for efficiency)
|
|
# - Decay duration (waits before reacting to door/window changes)
|
|
# - Emergency threshold (forces device ON below critical value)
|
|
# - Schedule support (only runs during scheduled times)
|
|
# - Power monitoring (detects device malfunction)
|
|
# - House-wide and room-specific window/door sensors
|
|
#
|
|
# Control Logic (in priority order):
|
|
# 1. If Force ON switch is ON → FORCE ON (manual override)
|
|
# 2. If value is below emergency threshold → FORCE ON (safety override)
|
|
# 3. If control switch is OFF → FORCE OFF
|
|
# 4. If environment not sealed OR schedule not active → OFF
|
|
# 5. If value at or above target → OFF (target reached)
|
|
# 6. If value below turn-on threshold (target - hysteresis) → ON
|
|
# 7. Otherwise → maintain current state (in hysteresis zone)
|
|
#
|
|
# Hysteresis Example (prevents rapid cycling):
|
|
# - Target humidity: 30%, Hysteresis window: 5%
|
|
# - Device turns OFF when humidity reaches 30%
|
|
# - Device turns ON when humidity drops to 25% (30% - 5%)
|
|
# - Between 25-30%: device maintains its current state
|
|
#
|
|
# Window/Door Logic:
|
|
# - "House closed" = ALL house windows are closed (for decay duration)
|
|
# - "Room closed" = ALL room windows AND doors are closed (for decay duration)
|
|
# - Device can run if EITHER house OR room is fully closed
|
|
#
|
|
# Power Monitoring:
|
|
# - If device is ON but power consumption is below threshold for
|
|
# decay duration, it's flagged as problematic (possible malfunction)
|
|
#
|
|
# Requirements:
|
|
# - Device entity to monitor state (switch, climate, etc.)
|
|
# - Custom actions for turning device on/off
|
|
# - Control switch (master enable/disable)
|
|
# - Environment sensor(s) for current value
|
|
# - Target value entity (input_number)
|
|
#
|
|
# Device Control Flexibility:
|
|
# - Supports any controllable device type via custom actions
|
|
# - Examples: switches, climate entities, smart remotes, scripts, scenes
|
|
# - Define your own turn_on and turn_off actions for maximum flexibility
|
|
#
|
|
# Author: Alexei Dolgolyov (dolgolyov.alexei@gmail.com)
|
|
# =============================================================================
|
|
|
|
blueprint:
|
|
name: "Custom: Climate Device Control"
|
|
description: >
|
|
Controls climate devices based on window/door sensors with decay duration
|
|
and value threshold for temperature, humidity, or other environmental control.
|
|
Supports any device type (switches, climate entities, smart remotes, etc.)
|
|
through customizable turn on/off actions.
|
|
domain: automation
|
|
|
|
# ===========================================================================
|
|
# INPUT CONFIGURATION
|
|
# ===========================================================================
|
|
input:
|
|
|
|
# -------------------------------------------------------------------------
|
|
# General Settings
|
|
# -------------------------------------------------------------------------
|
|
primary_group:
|
|
name: "General"
|
|
collapsed: false
|
|
input:
|
|
device_entity:
|
|
name: Device Entity
|
|
description: >
|
|
Entity used to monitor the device state (on/off).
|
|
Can be a switch, climate entity, or any entity with on/off states.
|
|
This is used for power monitoring and state checks.
|
|
selector:
|
|
entity:
|
|
domain:
|
|
- switch
|
|
- climate
|
|
- fan
|
|
- light
|
|
- input_boolean
|
|
|
|
turn_on_action:
|
|
name: Turn On Action
|
|
description: >
|
|
Action to execute when the device should be turned ON.
|
|
Examples:
|
|
- For switch: switch.turn_on with entity_id
|
|
- For climate: climate.turn_on or climate.set_hvac_mode
|
|
- For smart remote: remote.send_command with your IR/RF code
|
|
- For script: script.turn_on
|
|
selector:
|
|
action: {}
|
|
|
|
turn_off_action:
|
|
name: Turn Off Action
|
|
description: >
|
|
Action to execute when the device should be turned OFF.
|
|
Examples:
|
|
- For switch: switch.turn_off with entity_id
|
|
- For climate: climate.turn_off or climate.set_hvac_mode to 'off'
|
|
- For smart remote: remote.send_command with your IR/RF code
|
|
- For script: script.turn_on (for off script)
|
|
selector:
|
|
action: {}
|
|
|
|
control_switch:
|
|
name: Control Switch
|
|
description: >
|
|
Master switch that enables/disables this automation.
|
|
When OFF, the device will be turned off regardless of other conditions.
|
|
selector:
|
|
entity:
|
|
domain:
|
|
- binary_sensor
|
|
- input_boolean
|
|
|
|
force_on_entity:
|
|
name: Force ON Switch (optional)
|
|
description: >
|
|
When this entity is ON, the device will be FORCED ON regardless of
|
|
all other conditions (except being higher priority than emergency).
|
|
Useful for manual override when you want the device always running.
|
|
Leave empty to disable this feature.
|
|
default: []
|
|
selector:
|
|
entity:
|
|
domain:
|
|
- input_boolean
|
|
- switch
|
|
- binary_sensor
|
|
multiple: true
|
|
|
|
# -------------------------------------------------------------------------
|
|
# Doors & Windows Configuration
|
|
# -------------------------------------------------------------------------
|
|
doors_group:
|
|
name: "Doors & Windows"
|
|
collapsed: false
|
|
input:
|
|
house_windows:
|
|
name: House Window Sensors
|
|
description: >
|
|
Window sensors for the entire house. If ANY is open, device may turn off.
|
|
Leave empty if not using house-wide window monitoring.
|
|
default: []
|
|
selector:
|
|
entity:
|
|
domain: binary_sensor
|
|
multiple: true
|
|
|
|
room_windows:
|
|
name: Room Window Sensors
|
|
description: >
|
|
Window sensors for the room where the device is located.
|
|
Device can run when room is sealed (all closed).
|
|
default: []
|
|
selector:
|
|
entity:
|
|
domain: binary_sensor
|
|
multiple: true
|
|
|
|
room_doors:
|
|
name: Room Door Sensors
|
|
description: >
|
|
Door sensors for the room where the device is located.
|
|
Combined with room windows to determine if room is sealed.
|
|
default: []
|
|
selector:
|
|
entity:
|
|
domain: binary_sensor
|
|
multiple: true
|
|
|
|
decay_duration:
|
|
name: Decay Duration (seconds)
|
|
description: >
|
|
Time to wait after a door/window state change before reacting.
|
|
Prevents toggling when briefly opening doors.
|
|
default: 3
|
|
selector:
|
|
number:
|
|
min: 0
|
|
max: 600
|
|
unit_of_measurement: seconds
|
|
mode: slider
|
|
|
|
# -------------------------------------------------------------------------
|
|
# Environment Sensors & Target
|
|
# -------------------------------------------------------------------------
|
|
env_group:
|
|
name: "Environment"
|
|
collapsed: false
|
|
input:
|
|
env_sensors:
|
|
name: Environment Sensors
|
|
description: >
|
|
Sensors that measure the current environmental value
|
|
(temperature, humidity, etc.) in the room.
|
|
default: []
|
|
selector:
|
|
entity:
|
|
domain: sensor
|
|
multiple: true
|
|
|
|
target_value_entity:
|
|
name: Target Value Entity
|
|
description: >
|
|
Entity (e.g., input_number) that defines the target value.
|
|
Device turns OFF when sensor value reaches this target.
|
|
selector:
|
|
entity:
|
|
domain: input_number
|
|
|
|
hysteresis_window:
|
|
name: Hysteresis Window
|
|
description: >
|
|
Buffer zone to prevent rapid on/off cycling.
|
|
Device turns ON when value drops below (target - window).
|
|
Example: Target 30%, window 5% → turns OFF at 30%, turns ON at 25%.
|
|
Set to 0 to disable hysteresis (device toggles exactly at target).
|
|
default: 0
|
|
selector:
|
|
number:
|
|
min: 0
|
|
max: 50
|
|
step: 0.5
|
|
mode: slider
|
|
|
|
value_threshold:
|
|
name: Emergency Threshold
|
|
description: >
|
|
If ANY sensor value falls below this threshold, device will be
|
|
FORCED ON regardless of other conditions (emergency override).
|
|
Set to 0 to disable this feature.
|
|
default: 0
|
|
selector:
|
|
number:
|
|
min: 0
|
|
max: 100
|
|
mode: slider
|
|
|
|
value_is_low_entity:
|
|
name: "Low Value Indicator Entity (optional)"
|
|
description: >
|
|
Optional input_boolean that will be turned ON when value is
|
|
below the emergency threshold. Useful for dashboard indicators.
|
|
default: null
|
|
selector:
|
|
entity:
|
|
domain:
|
|
- input_boolean
|
|
|
|
# -------------------------------------------------------------------------
|
|
# Schedule Configuration
|
|
# -------------------------------------------------------------------------
|
|
schedule_group:
|
|
name: "Schedules"
|
|
collapsed: false
|
|
input:
|
|
schedule_entities:
|
|
name: Schedules (optional)
|
|
description: >
|
|
Schedule entities that define when the device may run.
|
|
Device only operates when ANY schedule is active (ON).
|
|
Leave empty to allow running at any time.
|
|
default: []
|
|
selector:
|
|
entity:
|
|
domain: schedule
|
|
multiple: true
|
|
|
|
# -------------------------------------------------------------------------
|
|
# Power Monitoring
|
|
# -------------------------------------------------------------------------
|
|
power_group:
|
|
name: "Power"
|
|
collapsed: false
|
|
input:
|
|
power_sensor:
|
|
name: Power Sensor
|
|
description: "Sensor reporting device power consumption (W)"
|
|
selector:
|
|
entity:
|
|
domain: sensor
|
|
|
|
power_threshold:
|
|
name: Power Threshold (W)
|
|
description: >
|
|
If device is ON but power consumption is below this value,
|
|
it may indicate a malfunction (e.g., heater element failure).
|
|
default: 10
|
|
selector:
|
|
number:
|
|
min: 0
|
|
max: 50
|
|
unit_of_measurement: "W"
|
|
|
|
power_decay_duration:
|
|
name: Power Decay Duration (s)
|
|
description: >
|
|
Time to wait after power reading changes before flagging
|
|
as problematic. Prevents false alarms during startup.
|
|
default: 10
|
|
selector:
|
|
number:
|
|
min: 1
|
|
max: 50
|
|
unit_of_measurement: "s"
|
|
|
|
power_problematic_indicator_entity:
|
|
name: Power Problem Indicator Entity (optional)
|
|
description: >
|
|
Optional input_boolean that will be turned ON when the device
|
|
appears to be malfunctioning (ON but low power consumption).
|
|
default: null
|
|
selector:
|
|
entity:
|
|
domain: input_boolean
|
|
|
|
# =============================================================================
|
|
# AUTOMATION MODE
|
|
# =============================================================================
|
|
# Single mode prevents multiple simultaneous executions
|
|
mode: single
|
|
|
|
# =============================================================================
|
|
# TRIGGERS
|
|
# =============================================================================
|
|
trigger:
|
|
# Control switch state changed
|
|
- platform: state
|
|
entity_id: !input control_switch
|
|
|
|
# Force ON switch state changed
|
|
- platform: state
|
|
entity_id: !input force_on_entity
|
|
|
|
# House window sensor changed (with decay delay)
|
|
- platform: state
|
|
entity_id: !input house_windows
|
|
for:
|
|
seconds: !input decay_duration
|
|
|
|
# Room window sensor changed (with decay delay)
|
|
- platform: state
|
|
entity_id: !input room_windows
|
|
for:
|
|
seconds: !input decay_duration
|
|
|
|
# Room door sensor changed (with decay delay)
|
|
- platform: state
|
|
entity_id: !input room_doors
|
|
for:
|
|
seconds: !input decay_duration
|
|
|
|
# Target value changed
|
|
- platform: state
|
|
entity_id: !input target_value_entity
|
|
|
|
# Environment sensor value changed
|
|
- platform: state
|
|
entity_id: !input env_sensors
|
|
|
|
# Power sensor dropped below threshold (potential malfunction)
|
|
- platform: numeric_state
|
|
entity_id: !input power_sensor
|
|
below: !input power_threshold
|
|
for:
|
|
seconds: !input power_decay_duration
|
|
|
|
# =============================================================================
|
|
# CONDITIONS
|
|
# =============================================================================
|
|
condition: []
|
|
|
|
# =============================================================================
|
|
# ACTIONS
|
|
# =============================================================================
|
|
action:
|
|
- variables:
|
|
# -----------------------------------------------------------------------
|
|
# Input Variables
|
|
# -----------------------------------------------------------------------
|
|
env_sensors: !input env_sensors
|
|
control_switch: !input control_switch
|
|
device_entity: !input device_entity
|
|
threshold: !input value_threshold
|
|
value_is_low_entity: !input value_is_low_entity
|
|
force_on_entity: !input force_on_entity
|
|
hysteresis_window: !input hysteresis_window
|
|
|
|
# -----------------------------------------------------------------------
|
|
# Force ON Check
|
|
# -----------------------------------------------------------------------
|
|
# Check if any force ON entity is enabled (list may be empty)
|
|
is_force_on: >
|
|
{{ force_on_entity | length > 0 and force_on_entity | select('is_state', 'on') | list | length > 0 }}
|
|
|
|
# -----------------------------------------------------------------------
|
|
# Target Value & Hysteresis
|
|
# -----------------------------------------------------------------------
|
|
target_value_entity: !input target_value_entity
|
|
target_value: "{{ states(target_value_entity) | float(0) }}"
|
|
# Turn-on threshold accounts for hysteresis window
|
|
turn_on_threshold: "{{ target_value - hysteresis_window }}"
|
|
|
|
# -----------------------------------------------------------------------
|
|
# Value Statistics
|
|
# -----------------------------------------------------------------------
|
|
# Calculate sensor counts for different thresholds
|
|
# Returns: [count_below_emergency, count_below_turn_on, count_at_or_above_target]
|
|
value_stats: >
|
|
{% set result = [] %}
|
|
{% if env_sensors | length > 0 %}
|
|
{% set values = expand(env_sensors) | map(attribute='state') | map('float', default=0) | list %}
|
|
{# Count sensors below emergency threshold #}
|
|
{% if threshold != 0 %}
|
|
{% set result = result + [values | select('lt', threshold) | list | count] %}
|
|
{% else %}
|
|
{% set result = result + [0] %}
|
|
{% endif %}
|
|
{# Count sensors below turn-on threshold (target - hysteresis) #}
|
|
{% if turn_on_threshold != 0 %}
|
|
{% set result = result + [values | select('lt', turn_on_threshold) | list | count] %}
|
|
{% else %}
|
|
{% set result = result + [0] %}
|
|
{% endif %}
|
|
{# Count sensors at or above target value (for turn-off decision) #}
|
|
{% if target_value != 0 %}
|
|
{% set result = result + [values | select('ge', target_value) | list | count] %}
|
|
{% else %}
|
|
{% set result = result + [0] %}
|
|
{% endif %}
|
|
{% else %}
|
|
{% set result = [0, 0, 0] %}
|
|
{% endif %}
|
|
{{ result }}
|
|
|
|
# True if ANY sensor is below the emergency threshold
|
|
is_value_below_threshold: "{{ (value_stats[0] | int) > 0 }}"
|
|
# True if ANY sensor is below the turn-on threshold (target - hysteresis)
|
|
is_value_below_turn_on_threshold: "{{ (value_stats[1] | int) > 0 }}"
|
|
# True if ALL sensors are at or above the target value
|
|
is_value_at_or_above_target: "{{ (value_stats[2] | int) == (env_sensors | length) and (env_sensors | length) > 0 }}"
|
|
|
|
# -----------------------------------------------------------------------
|
|
# Power Monitoring
|
|
# -----------------------------------------------------------------------
|
|
power_threshold: !input power_threshold
|
|
power_sensor: !input power_sensor
|
|
power_problematic_indicator_entity: !input power_problematic_indicator_entity
|
|
power_decay_duration: !input power_decay_duration
|
|
power: "{{ states(power_sensor) | float(0) }}"
|
|
# Device is problematic if it's consuming power but below threshold
|
|
is_power_not_ok: "{{ (power > 0 and power < power_threshold) if power_threshold != 0 else false }}"
|
|
|
|
# -----------------------------------------------------------------------
|
|
# Window/Door State
|
|
# -----------------------------------------------------------------------
|
|
house_windows: !input house_windows
|
|
room_windows: !input room_windows
|
|
room_doors: !input room_doors
|
|
decay: !input decay_duration
|
|
|
|
# Check if ALL house windows are closed (for decay duration)
|
|
house_closed: >
|
|
{% if house_windows | length == 0 %}
|
|
{{ false }}
|
|
{% else %}
|
|
{% set ns = namespace(res = true) %}
|
|
{% for it in house_windows %}
|
|
{% set time_closed = (now() - states[it].last_changed).total_seconds() %}
|
|
{% set ns.res = ns.res and (is_state(it, 'off') and time_closed > decay) %}
|
|
{% endfor %}
|
|
{{ ns.res }}
|
|
{% endif %}
|
|
|
|
# Check if ALL room windows AND doors are closed (for decay duration)
|
|
# BUG FIX: Original had wrong operator precedence in condition
|
|
room_closed: >
|
|
{% set window_count = room_windows | length %}
|
|
{% set door_count = room_doors | length %}
|
|
{% if window_count == 0 and door_count == 0 %}
|
|
{{ false }}
|
|
{% else %}
|
|
{% set ns = namespace(res = true) %}
|
|
{# Check all room windows #}
|
|
{% for it in room_windows %}
|
|
{% set time_closed = (now() - states[it].last_changed).total_seconds() %}
|
|
{% set ns.res = ns.res and (is_state(it, 'off') and time_closed > decay) %}
|
|
{% endfor %}
|
|
{# Check all room doors #}
|
|
{% for it in room_doors %}
|
|
{% set time_closed = (now() - states[it].last_changed).total_seconds() %}
|
|
{% set ns.res = ns.res and (is_state(it, 'off') and time_closed > decay) %}
|
|
{% endfor %}
|
|
{{ ns.res }}
|
|
{% endif %}
|
|
|
|
# -----------------------------------------------------------------------
|
|
# Schedule Check
|
|
# -----------------------------------------------------------------------
|
|
schedule_entities: !input schedule_entities
|
|
# True if any schedule is active, or if no schedules are configured
|
|
schedule_active: >
|
|
{% if schedule_entities | length > 0 %}
|
|
{{ schedule_entities | select('is_state', 'on') | list | length > 0 }}
|
|
{% else %}
|
|
{{ true }}
|
|
{% endif %}
|
|
|
|
# -----------------------------------------------------------------------
|
|
# Debug Flag
|
|
# -----------------------------------------------------------------------
|
|
is_debug: false
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# DEBUG: Log current state
|
|
# ---------------------------------------------------------------------------
|
|
- choose:
|
|
- conditions: "{{ is_debug }}"
|
|
sequence:
|
|
- service: persistent_notification.create
|
|
data:
|
|
title: "Climate Controller (debug)"
|
|
message: >
|
|
is_force_on = {{ is_force_on }},
|
|
room_closed = {{ room_closed }},
|
|
house_closed = {{ house_closed }},
|
|
is_value_below_threshold = {{ is_value_below_threshold }},
|
|
is_value_below_turn_on_threshold = {{ is_value_below_turn_on_threshold }},
|
|
is_value_at_or_above_target = {{ is_value_at_or_above_target }},
|
|
target_value = {{ target_value }},
|
|
turn_on_threshold = {{ turn_on_threshold }},
|
|
schedule_active = {{ schedule_active }},
|
|
control_switch = {{ states(control_switch) }}
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# POWER MONITORING: Flag device if malfunctioning
|
|
# ---------------------------------------------------------------------------
|
|
# Note: For climate entities, 'on' state check works for most HVAC modes.
|
|
# For entities that don't use 'on' state, power monitoring may need adjustment.
|
|
- choose:
|
|
- conditions:
|
|
- condition: template
|
|
value_template: "{{ states(device_entity) not in ['off', 'unavailable', 'unknown'] and power_problematic_indicator_entity is not none }}"
|
|
sequence:
|
|
- variables:
|
|
# Check if enough time has passed since last power reading
|
|
timeout_elapsed: >
|
|
{% set last = as_timestamp(states[power_sensor].last_changed) %}
|
|
{{ (as_timestamp(now()) - last) > power_decay_duration }}
|
|
|
|
- condition: template
|
|
value_template: "{{ timeout_elapsed }}"
|
|
|
|
- choose:
|
|
# Power is problematic - flag the indicator
|
|
- conditions: "{{ is_power_not_ok }}"
|
|
sequence:
|
|
- service: input_boolean.turn_on
|
|
target:
|
|
entity_id: "{{ power_problematic_indicator_entity }}"
|
|
# Power is OK - clear the indicator
|
|
default:
|
|
- service: input_boolean.turn_off
|
|
target:
|
|
entity_id: "{{ power_problematic_indicator_entity }}"
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# LOW VALUE INDICATOR: Update the low value indicator entity
|
|
# ---------------------------------------------------------------------------
|
|
- choose:
|
|
- conditions:
|
|
- condition: template
|
|
value_template: "{{ value_is_low_entity is not none }}"
|
|
sequence:
|
|
- choose:
|
|
# Value is below threshold - turn on indicator
|
|
- conditions:
|
|
- condition: template
|
|
value_template: "{{ is_value_below_threshold }}"
|
|
sequence:
|
|
- service: input_boolean.turn_on
|
|
target:
|
|
entity_id: !input value_is_low_entity
|
|
# Value is OK - turn off indicator
|
|
default:
|
|
- service: input_boolean.turn_off
|
|
target:
|
|
entity_id: !input value_is_low_entity
|
|
|
|
# ===========================================================================
|
|
# MAIN CONTROL LOGIC (Priority Order)
|
|
# ===========================================================================
|
|
- choose:
|
|
|
|
# -----------------------------------------------------------------------
|
|
# PRIORITY 1: Force ON Override (Manual)
|
|
# -----------------------------------------------------------------------
|
|
# If force ON switch is enabled, FORCE device ON regardless of all else
|
|
- conditions:
|
|
- condition: template
|
|
value_template: "{{ is_force_on }}"
|
|
sequence: !input turn_on_action
|
|
|
|
# -----------------------------------------------------------------------
|
|
# PRIORITY 2: Emergency Override (Safety)
|
|
# -----------------------------------------------------------------------
|
|
# If value is below emergency threshold, FORCE device ON
|
|
- conditions:
|
|
- condition: template
|
|
value_template: "{{ is_value_below_threshold }}"
|
|
sequence: !input turn_on_action
|
|
|
|
# -----------------------------------------------------------------------
|
|
# PRIORITY 3: Control Switch Off
|
|
# -----------------------------------------------------------------------
|
|
# If master control is disabled, FORCE device OFF
|
|
- conditions:
|
|
- condition: template
|
|
value_template: "{{ is_state(control_switch, 'off') }}"
|
|
sequence: !input turn_off_action
|
|
|
|
# -----------------------------------------------------------------------
|
|
# PRIORITY 4: Environment Not Ready
|
|
# -----------------------------------------------------------------------
|
|
# If environment not sealed OR schedule not active, turn OFF
|
|
- conditions:
|
|
- condition: template
|
|
value_template: "{{ not (house_closed or room_closed) or not schedule_active }}"
|
|
sequence: !input turn_off_action
|
|
|
|
# -----------------------------------------------------------------------
|
|
# PRIORITY 5: Target Reached
|
|
# -----------------------------------------------------------------------
|
|
# If all sensors at or above target value, turn OFF
|
|
- conditions:
|
|
- condition: template
|
|
value_template: "{{ is_value_at_or_above_target }}"
|
|
sequence: !input turn_off_action
|
|
|
|
# -----------------------------------------------------------------------
|
|
# PRIORITY 6: Below Turn-On Threshold
|
|
# -----------------------------------------------------------------------
|
|
# If any sensor below turn-on threshold (target - hysteresis), turn ON
|
|
- conditions:
|
|
- condition: template
|
|
value_template: "{{ is_value_below_turn_on_threshold }}"
|
|
sequence: !input turn_on_action
|
|
|
|
# -------------------------------------------------------------------------
|
|
# DEFAULT: Maintain Current State (Hysteresis Zone)
|
|
# -------------------------------------------------------------------------
|
|
# Value is between turn-on threshold and target - don't change device state
|
|
# This prevents rapid on/off cycling when value is near the target
|
|
default: []
|