# Climate Device Controller Blueprint
|
|
|
|
This blueprint controls climate devices (heaters, AC, humidifiers, etc.) based on environmental sensors, window/door states, and schedules.
|
|
|
|
## Supported Device Types
|
|
|
|
Supports any controllable device type through custom actions:
|
|
|
|
- Switches (traditional on/off control)
|
|
- Climate entities (HVAC, air conditioners)
|
|
- Smart remotes (IR/RF commands for AC units)
|
|
- Scripts and scenes
|
|
- Any other controllable entity
|
|
|
|
## Features
|
|
|
|
- Automatic on/off based on target value (temperature, humidity, etc.)
|
|
- Hysteresis window to prevent rapid on/off cycling
|
|
- Force ON override (manual override to keep device always on)
|
|
- Window/door sensor integration (turns off when open for efficiency)
|
|
- Decay duration (waits before reacting to door/window changes)
|
|
- Emergency threshold (forces device ON below critical value)
|
|
- Schedule support (only runs during scheduled times)
|
|
- Power monitoring (detects device malfunction)
|
|
- House-wide and room-specific window/door sensors
|
|
|
|
## Control Logic (Priority Order)
|
|
|
|
1. If Force ON switch is ON → FORCE ON (manual override)
|
|
2. If value is below emergency threshold → FORCE ON (safety override)
|
|
3. If control switch is OFF → FORCE OFF
|
|
4. If environment not sealed OR schedule not active → OFF
|
|
5. If value at or above target → OFF (target reached)
|
|
6. If value below turn-on threshold (target - hysteresis) → ON
|
|
7. Otherwise → maintain current state (in hysteresis zone)
|
|
|
|
## Hysteresis Example
|
|
|
|
Prevents rapid cycling:
|
|
|
|
- Target humidity: 30%, Hysteresis window: 5%
|
|
- Device turns OFF when humidity reaches 30%
|
|
- Device turns ON when humidity drops to 25% (30% - 5%)
|
|
- Between 25-30%: device maintains its current state
|
|
|
|
## Window/Door Logic
|
|
|
|
- "House closed" = ALL house windows are closed (for decay duration)
|
|
- "Room closed" = ALL room windows AND doors are closed (for decay duration)
|
|
- Device can run if EITHER house OR room is fully closed
|
|
|
|
## Power Monitoring
|
|
|
|
If device is ON but power consumption is below threshold for decay duration, it's flagged as problematic (possible malfunction).
|
|
|
|
## Requirements
|
|
|
|
- Device entity to monitor state (switch, climate, etc.)
|
|
- Custom actions for turning device on/off
|
|
- Control switch (master enable/disable)
|
|
- Environment sensor(s) for current value
|
|
- Target value entity (input_number)
|
|
|
|
## Author
|
|
|
|
Alexei Dolgolyov (dolgolyov.alexei@gmail.com)
|