- Detect primary monitor via Windows EnumDisplayMonitors API and show badge - Expand accent color picker with 9 presets and custom color input - Auto-generate hover color for custom accent colors - Re-render accent swatches on locale change for proper i18n - Replace restart-server.bat with PowerShell restart-server.ps1 Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
272 lines
8.0 KiB
Python
272 lines
8.0 KiB
Python
"""Display brightness and power control service."""
|
|
|
|
import ctypes
|
|
import ctypes.wintypes
|
|
import logging
|
|
import platform
|
|
import struct
|
|
import time
|
|
from dataclasses import dataclass, field
|
|
|
|
logger = logging.getLogger(__name__)
|
|
|
|
_sbc = None
|
|
_monitorcontrol = None
|
|
|
|
|
|
def _load_sbc():
|
|
global _sbc
|
|
if _sbc is None:
|
|
try:
|
|
import screen_brightness_control as sbc
|
|
_sbc = sbc
|
|
except ImportError:
|
|
logger.warning("screen_brightness_control not installed - brightness control unavailable")
|
|
return _sbc
|
|
|
|
|
|
def _load_monitorcontrol():
|
|
global _monitorcontrol
|
|
if _monitorcontrol is None:
|
|
try:
|
|
import monitorcontrol
|
|
_monitorcontrol = monitorcontrol
|
|
except ImportError:
|
|
logger.warning("monitorcontrol not installed - display power control unavailable")
|
|
return _monitorcontrol
|
|
|
|
|
|
def _parse_edid_resolution(edid_hex: str) -> str | None:
|
|
"""Parse resolution from EDID hex string (first detailed timing descriptor)."""
|
|
try:
|
|
edid = bytes.fromhex(edid_hex)
|
|
if len(edid) < 58:
|
|
return None
|
|
dtd = edid[54:]
|
|
pixel_clock = struct.unpack('<H', dtd[0:2])[0]
|
|
if pixel_clock == 0:
|
|
return None
|
|
h_active = dtd[2] | ((dtd[4] >> 4) << 8)
|
|
v_active = dtd[5] | ((dtd[7] >> 4) << 8)
|
|
return f"{h_active}x{v_active}"
|
|
except Exception:
|
|
return None
|
|
|
|
|
|
@dataclass
|
|
class MonitorInfo:
|
|
id: int
|
|
name: str
|
|
brightness: int | None
|
|
power_supported: bool
|
|
power_on: bool = True
|
|
model: str = ""
|
|
manufacturer: str = ""
|
|
resolution: str | None = None
|
|
is_primary: bool = False
|
|
|
|
def to_dict(self) -> dict:
|
|
return {
|
|
"id": self.id,
|
|
"name": self.name,
|
|
"brightness": self.brightness,
|
|
"power_supported": self.power_supported,
|
|
"power_on": self.power_on,
|
|
"model": self.model,
|
|
"manufacturer": self.manufacturer,
|
|
"resolution": self.resolution,
|
|
"is_primary": self.is_primary,
|
|
}
|
|
|
|
|
|
def _detect_primary_resolution() -> str | None:
|
|
"""Detect the primary display resolution via Windows API."""
|
|
if platform.system() != "Windows":
|
|
return None
|
|
try:
|
|
class MONITORINFO(ctypes.Structure):
|
|
_fields_ = [
|
|
("cbSize", ctypes.wintypes.DWORD),
|
|
("rcMonitor", ctypes.wintypes.RECT),
|
|
("rcWork", ctypes.wintypes.RECT),
|
|
("dwFlags", ctypes.wintypes.DWORD),
|
|
]
|
|
|
|
MONITORINFOF_PRIMARY = 1
|
|
primary_res = None
|
|
|
|
def callback(hmon, hdc, rect, data):
|
|
nonlocal primary_res
|
|
mi = MONITORINFO()
|
|
mi.cbSize = ctypes.sizeof(mi)
|
|
ctypes.windll.user32.GetMonitorInfoW(hmon, ctypes.byref(mi))
|
|
if mi.dwFlags & MONITORINFOF_PRIMARY:
|
|
w = mi.rcMonitor.right - mi.rcMonitor.left
|
|
h = mi.rcMonitor.bottom - mi.rcMonitor.top
|
|
primary_res = f"{w}x{h}"
|
|
return True
|
|
|
|
MONITORENUMPROC = ctypes.WINFUNCTYPE(
|
|
ctypes.c_int,
|
|
ctypes.wintypes.HMONITOR,
|
|
ctypes.wintypes.HDC,
|
|
ctypes.POINTER(ctypes.wintypes.RECT),
|
|
ctypes.wintypes.LPARAM,
|
|
)
|
|
ctypes.windll.user32.EnumDisplayMonitors(
|
|
None, None, MONITORENUMPROC(callback), 0
|
|
)
|
|
return primary_res
|
|
except Exception:
|
|
return None
|
|
|
|
|
|
def _mark_primary(monitors: list[MonitorInfo]) -> None:
|
|
"""Mark the primary display in the monitor list."""
|
|
if not monitors:
|
|
return
|
|
|
|
primary_res = _detect_primary_resolution()
|
|
if primary_res:
|
|
for m in monitors:
|
|
if m.resolution == primary_res:
|
|
m.is_primary = True
|
|
return
|
|
|
|
# Fallback: mark first monitor as primary
|
|
monitors[0].is_primary = True
|
|
|
|
|
|
# Cache for monitor list
|
|
_monitor_cache: list[MonitorInfo] | None = None
|
|
_cache_time: float = 0
|
|
_CACHE_TTL = 5.0 # seconds
|
|
|
|
|
|
def list_monitors(force_refresh: bool = False) -> list[MonitorInfo]:
|
|
"""List all connected monitors with their current brightness."""
|
|
global _monitor_cache, _cache_time
|
|
|
|
if not force_refresh and _monitor_cache is not None and (time.time() - _cache_time) < _CACHE_TTL:
|
|
return _monitor_cache
|
|
|
|
sbc = _load_sbc()
|
|
if sbc is None:
|
|
return []
|
|
|
|
monitors = []
|
|
try:
|
|
info_list = sbc.list_monitors_info()
|
|
brightnesses = sbc.get_brightness()
|
|
|
|
# Get DDC/CI monitors for power state
|
|
mc = _load_monitorcontrol()
|
|
ddc_monitors = []
|
|
if mc:
|
|
try:
|
|
ddc_monitors = mc.get_monitors()
|
|
except Exception:
|
|
pass
|
|
|
|
for i, info in enumerate(info_list):
|
|
name = info.get("name", f"Monitor {i}")
|
|
model = info.get("model", "")
|
|
manufacturer = info.get("manufacturer", "")
|
|
brightness = brightnesses[i] if i < len(brightnesses) else None
|
|
# VCP method monitors support DDC/CI power control
|
|
method = str(info.get("method", "")).lower()
|
|
power_supported = "vcp" in method
|
|
|
|
# Parse resolution from EDID
|
|
edid = info.get("edid", "")
|
|
resolution = _parse_edid_resolution(edid) if edid else None
|
|
|
|
# Read power state via DDC/CI
|
|
power_on = True
|
|
if power_supported and i < len(ddc_monitors):
|
|
try:
|
|
with ddc_monitors[i] as mon:
|
|
power_mode = mon.get_power_mode()
|
|
power_on = power_mode == mc.PowerMode.on
|
|
except Exception:
|
|
pass
|
|
|
|
monitors.append(MonitorInfo(
|
|
id=i,
|
|
name=name,
|
|
brightness=brightness,
|
|
power_supported=power_supported,
|
|
power_on=power_on,
|
|
model=model,
|
|
manufacturer=manufacturer,
|
|
resolution=resolution,
|
|
))
|
|
except Exception as e:
|
|
logger.error("Failed to enumerate monitors: %s", e)
|
|
|
|
_mark_primary(monitors)
|
|
_monitor_cache = monitors
|
|
_cache_time = time.time()
|
|
return monitors
|
|
|
|
|
|
def get_brightness(monitor_id: int) -> int | None:
|
|
"""Get brightness for a specific monitor."""
|
|
sbc = _load_sbc()
|
|
if sbc is None:
|
|
return None
|
|
try:
|
|
result = sbc.get_brightness(display=monitor_id)
|
|
if isinstance(result, list):
|
|
return result[0] if result else None
|
|
return result
|
|
except Exception as e:
|
|
logger.error("Failed to get brightness for monitor %d: %s", monitor_id, e)
|
|
return None
|
|
|
|
|
|
def set_brightness(monitor_id: int, value: int) -> bool:
|
|
"""Set brightness for a specific monitor (0-100)."""
|
|
sbc = _load_sbc()
|
|
if sbc is None:
|
|
return False
|
|
|
|
value = max(0, min(100, value))
|
|
try:
|
|
sbc.set_brightness(value, display=monitor_id)
|
|
# Invalidate cache
|
|
global _monitor_cache
|
|
_monitor_cache = None
|
|
return True
|
|
except Exception as e:
|
|
logger.error("Failed to set brightness for monitor %d: %s", monitor_id, e)
|
|
return False
|
|
|
|
|
|
def set_power(monitor_id: int, on: bool) -> bool:
|
|
"""Turn a monitor on or off via DDC/CI."""
|
|
mc = _load_monitorcontrol()
|
|
if mc is None:
|
|
logger.error("monitorcontrol not available for power control")
|
|
return False
|
|
|
|
try:
|
|
ddc_monitors = mc.get_monitors()
|
|
if monitor_id >= len(ddc_monitors):
|
|
logger.error("Monitor %d not found in DDC/CI monitors", monitor_id)
|
|
return False
|
|
|
|
with ddc_monitors[monitor_id] as monitor:
|
|
if on:
|
|
monitor.set_power_mode(mc.PowerMode.on)
|
|
else:
|
|
monitor.set_power_mode(mc.PowerMode.off_soft)
|
|
|
|
# Invalidate cache
|
|
global _monitor_cache
|
|
_monitor_cache = None
|
|
return True
|
|
except Exception as e:
|
|
logger.error("Failed to set power for monitor %d: %s", monitor_id, e)
|
|
return False
|